Pultrusion is a high speed process for producing continuous lengths of reinforced polymer structural shapes with constant cross-sections.

Two different methods are used for impregnation:
1.    Liquid resin is continuously injected into a mold where it impregnates the reinforcement
2.    Liquid resin impregnates the fibers before the impregnated fibers enter in the mold.

The mold is at a constant temperature allowing the resin to cure. Finished parts are then cut to the desired length. The reinforcement materials are in continuous forms such as rolls of fiber mat and doffs of fiber rovings.

Main benefits:

  • Fast and cost effective
  • Material properties and profile design can be optimized for each individual project.

 


Product Designation Features Viscosity
(cps/°F)
Gel Time
(Min./°F)
Cure Cycle
(Time/°F)
Tg
(°F)
Flexural Strength (kpsi) Tensile Strength (kpsi) Fracture Properties
K‚á´„
(ˆšin*lb/in²)
G‚á´„ (In*lb/in²)
Araldite LY 1564 / Aradur 917 / Accelerator 960-1 Intermediate temp. use / Very good ultimate properties / Anhydride system 550 / 77 30 – 40 / 176
8 – 13 / 212
3 – 5 / 248
1 – 2 / 284
4h / 176
4h / 284
252 – 266 20.3 – 21.7 20.3 – 21.8 648 – 769 0.57 – 0.71
Resin XU 3508 / Aradur 917 / Accelerator DY070 Toughened / Intermediate temp. use / Anhydride system 640 / 77 9 / 248
3 / 284
4h / 176
4h / 284
275 – 293 20.3 – 21.8 10.9 – 11.6 934 – 1,044 1.2 – 1.37
Aradlite LY 1556 / Aradur 22962 Short pot life / Intermediate temp. use 1,900 / 77 18 – 22 / 176
7 – 10 / 212
3 – 5 / 248
1h / 248
2h / 302
298 – 316 18.9 – 19.7 8.9 – 10.4 747 – 857 0.80 – 1.0
Araldite LY 1556 / Aradur 917 / Accelerator DY 070 Intermediate temp. use / Anhydride system 750 / 25 35 – 45 / 212
10 – 12 / 284
1 – 2 / 320
4h / 176
4h a/302
302 – 311 18.1 – 19.6 12.0 – 13.5 934 – 1,044 1.2 – 1.37
Araldite LY 1556 / Aradur 906 / Accelerator DY 070 High temp. use / Anhydride system 2,000 / 77 14 – 16 / 248 2h / 248
4h / 320
4h / 356
340 – 350 14.4 – 20.3 6.5 – 8.7 659 – 924 0.57 – 0.70
XU 9509 / Aradur 906 / Accelerator DY 070 High temp. use / Low viscosity / Anhydride system 100 – 250 / 77 14 – 16 / 248
1 – 3 / 356
2h at 257
2h at 430
410 – 420 12.2 304 2.8 6.6 305 2.8 758 1.12 758 1.12

Find a TDS